> For clean Markdown of any page, append .md to the page URL. > For a complete documentation index, see https://mediakind.ferndocs.com/beam/system-admin/iso-installation/raid-configuration/llms.txt. > For AI client integration (Claude Code, Cursor, etc.), connect to the MCP server at https://mediakind.ferndocs.com/_mcp/server. # RAID and FakeRAID configuration This page covers the disk RAID configurations supported for the MK.IO Beam system drive. **RAID vs FakeRAID:** With hardware RAID, the controller assembles the array itself and presents it to the OS as a single ordinary disk (`/dev/sdX`). With FakeRAID, the controller only stores RAID metadata; the OS assembles the array in software, and it appears as `/dev/mdX` with the member disks still visible separately. Check the controller model in the server’s RAID/BIOS utility or management console (for example, iDRAC) to determine which type is in use. **Sector size:** From MK.IO Beam 1.14.0, the system drive may use either a 512-byte or a 4Kn (4096-byte) sector size. On earlier releases it must be 512 bytes: installation onto a 4Kn drive fails when the installer mounts the boot partition. ## Hardware RAID Hardware RAID has always been supported for the MK.IO Beam system drive. Before 1.14.0 the virtual disk must be created with a 512-byte block size; from 1.14.0 a 4096-byte block size is also supported. Controllers often default to 4096, so check the block size when creating the virtual disk if the server is running an earlier release. ## FakeRAID From MK.IO Beam 1.14.0, FakeRAID is supported for the system drive. The following settings are required: | Setting | Value | | ----------- | ----------- | | Sector size | 512 or 4096 | | OS | RHEL | | RAID Type | Linux RAID | | RAID Level | RAID 1 |