> For clean Markdown of any page, append .md to the page URL. > For a complete documentation index, see https://mediakind.ferndocs.com/beam/receiver/output/sdi/llms.txt. > For AI client integration (Claude Code, Cursor, etc.), connect to the MCP server at https://mediakind.ferndocs.com/_mcp/server. # Configure SDI output The Receiver service on MK.IO Beam can output uncompressed digital video, audio, and ancillary data using the SDI output standards. ## Supported SDI Output Cards SDI output on MK.IO Beam requires supported hardware option cards. See the **SDI Output** section in the technical Reference documentation for a list of compatible cards. ## Configuring SDI Output ### Configuring ASI/SDI mode To use the card as a SDI output card it must be configured as follows (see also [Set up SDI/ASI cards](/beam/system-admin/maintenance/setup-sdi-asi-card/)): * Select Appliance from the left-hand side menu. * Click the ASI/SDI Interface tab. * Select the Slot Tab corresponding to the SDI/ASI card. If more than one card is present, there will be a separate slot tab for each card. * Select the appropriate ASI/SDI mode from the ASI/SDI Mode drop down menu. The description shows which SDI standards are supported (for example, UHD output may not be supported). * Click the Apply and Reboot button. * A confirmation pop-up window will appear asking, “Are you sure?” * Review any warnings or guidance provided. If you are sure, click Yes, configure and REBOOT! Otherwise, click Cancel to abort. * Following the reboot, refresh the web page. The reboot may take a few minutes to complete. ### Determine SDI output card Slot number SDI port selection is referenced with its card slot number to differentiate where multiple cards are fitted to the server. The card name/type for an assigned slot number can be determined using the following steps: * Select Appliance from the left-hand side menu. * Click the ASI/SDI Interface tab. * Select the Slot Tab corresponding to the SDI/ASI card. If more than one card is present, there will be a separate slot tab for each card. The selected Slot tab should list some useful data such as card model, serial number, etc. There is a known issue on some servers where the reported slot number does not match the slot number printed on the rear chassis. ### SDI output port Before you start, ensure at least one Receiver service is configured. * From the Home page, select the RECEIVER item from the required feed then click . * In the Parameters window, select the Output tab. * Select the SDI 1 tab. If the SDI tab is not present under the Output tab: Click the to bring up a prompt to add a new output * Select SDI from the drop down menu * Click the Add button to complete and add the SDI output tab * Select the SDI port required from the drop down menu. * Select any required video options as detailed in the SDI output parameters section SDI ports in use by other running services are listed in the drop-down menu, along with the associated service name. A service configured to use an **SDI port** that is already in use will be prevented from running. If an SDI port appears to be missing or listed as 3G-capable instead of 12G-capable, this may be due to the selected **ASI/SDI mode**. Refer to the **Configuring ASI/SDI mode** section to update the setting.